Probiotic Cold Chain

Shipment monitoring PAL-0427

Risk detected

Simulated prototype — no real sensors connected

Demo gateway connected
Last packet just now · 0 buffered readings

Ambient temperature

25.0°C

Loading zone

Control bottle

5.2°C

Currently within demo range

Predicted threshold crossing

≈ 2.5 min

If current conditions continue

Probiotic viability

Not assessed

Laboratory validation required

Control-bottle temperature

15 minutes of history and a 15-minute physical forecast

History Forecast
Simulated control-bottle temperature Historical temperature, the configured six degree threshold, and a fifteen minute forecast.
Configured demo threshold: 6°C. This is a prototype setting, not a food-safety limit.

Explore a scenario

Switch the simulated conditions to test the system response.

Loading / receiving

Increasing temperature during loading

A pallet waits in a warm loading zone. The forecast identifies a likely threshold crossing before the measured product temperature reaches it.

Interface illustration, not a finished application. All readings, alerts and forecasts on this page use synthetic data and a simplified thermal model. The system does not guarantee food safety.

01 / Prediction

A forecast with its assumptions in view

The dashboard uses Newton’s law of heating and cooling for its main forecast. A small linear-regression benchmark is included for comparison; threshold alerts themselves are not presented as AI.

Physical model

Tp(t + Δt) = Ta + (Tp(t) − Ta)e−kΔt
Tp
Control-bottle liquid temperature
Ta
Ambient air temperature
k
Thermal response coefficient, min⁻¹
Δt
Forecast horizon in minutes

A larger k means the liquid approaches ambient temperature faster. The coefficient is configured for this demonstration, not identified from a real bottle.

Regression benchmark

A three-coefficient linear regression predicts the next one-minute liquid temperature from the current liquid and ambient temperatures. It is recursively applied for longer horizons.

Training data
4,000 synthetic one-minute transitions
Inputs
Current liquid T and ambient T
Output
Liquid T one minute later
Held-out test
1,000 separate synthetic transitions

Synthetic histories use fixed k = 0.018 min⁻¹, liquid temperatures of 2–8°C, ambient temperatures of 2–28°C and seeded measurement noise. No experimental or bacterial-survival data is used.

Model comparison lab

Change the conditions and compare the next 15 minutes.

Synthetic experiment
2°C30°C
SlowerFaster
Physical at 15 min9.0°C
Regression at 15 min9.0°C
Persistence baseline5.2°C
Comparison of three temperature prediction methods Physical model, linear regression and persistence baseline over fifteen minutes.
Physical Regression Persistence
One-minute prediction error on 1,000 held-out synthetic samples
MethodWhat it doesRMSE
Persistence baselineAssumes the next temperature equals the current temperature—
Newton physical modelUses the known synthetic thermal coefficient—
Linear regressionLearns coefficients from the synthetic training set—

Limitations

  • Constant ambient temperature and thermal response are assumed during each forecast; opening doors, airflow and packaging change real behaviour.
  • The control bottle is a proxy for product temperature and does not capture variation across an entire pallet.
  • Regression error on synthetic data is not evidence of real-world accuracy. Experimental histories and independent validation are still required.
  • No CFU or probiotic-survival forecast is shown. A future viability model requires laboratory measurements and validation.

02 / System

Architecture from sensing to intervention

The existing two-sensor IoT concept is retained. Local buffering keeps readings during a connection loss; the early-warning output leads to an operator action, not an automatic safety claim.

Probiotic cold-chain system architecture Ambient and control-bottle sensors feed an ESP32 gateway with local storage. Connectivity sends data to temperature prediction, early warning and operator intervention. A future probiotic viability model remains dashed and requires laboratory data. Sensor 01 · I²C Ambient air temperature SHT31-D · loading / transport air Sensor 02 · 1-Wire Control-bottle temperature Waterproof DS18B20 probe Gateway ESP32 controller Timestamp · buffer · reconnect Wi-Fi / Bluetooth provisioning Data storage Local microSD + server Buffered sync after recovery Prediction layer Newton model + regression benchmark 5–15 minute product-temperature forecast Early-warning system Predicted threshold + alert Time to crossing · connection state Operator intervention Return pallet to cold storage New ambient condition → new forecast Future · laboratory data required Probiotic viability model Dashed component is architectural only. No CFU prediction is implemented or displayed.
Normal operation

Sensor readings are timestamped, stored and evaluated against the forecast threshold.

Connection loss

The gateway keeps readings locally and the interface marks the last received value as stale.

Recovery

Buffered readings are synchronised before live monitoring and forecasting resume.

03 / Hardware

Representative prototype bill of materials

One monitoring unit per pallet. These are representative development components for costing and energy estimates, not a production-certified hardware selection.

Specifications and supplier references
ComponentRole / qty.Connectivity & representative specificationEnergy / service consideration
Waterproof DS18B20 Adafruit 381 Control-bottle probe
1 per pallet
1-Wire digital output; 3.0–5.0 V systems; up to 12-bit resolution; ±0.5°C over much of the range. Supplier notes it is not IP-rated. Low-power digital sensor. Inspect cable and sealing regularly; do not assume suitability for corrosive washdown.
Sensirion SHT31-D Adafruit 2857 Ambient air sensor
1 per pallet
I²C, address 0x44 or 0x45; 3 V / 5 V compatible breakout; typical ±0.3°C temperature and ±2% RH accuracy. 2.4–5.5 V sensor supply per datasheet. Protect from condensation and allow airflow around the sensor.
ESP32-DevKitC-32E Espressif Gateway / logger
1 per pallet
ESP32-WROOM-32E; Wi-Fi and Bluetooth; GPIO for I²C, 1-Wire and SPI; USB-UART for programming. 5 V via USB or header, or 3.3 V header per hardware guide. Radio duty cycle dominates energy use; measure before battery sizing.
MicroSD breakout+ Adafruit 254 + microSD card Local outage buffer
1 per pallet
SPI storage; onboard 5 V to 3 V regulator and level shifting; supports 2 GB+ cards with suitable firmware / filesystem. Regulator supplies up to 150 mA for the card. Plan card replacement and data-integrity checks for the deployment environment.
Regulated 5 V USB supply Power option from DevKitC guide Prototype power
1 per pallet
USB supply for gateway and sensors; vehicle / facility supply and optional backup battery must be selected for the final installation. Size backup power only after measuring transmission, logging and sleep current. Rechargeable batteries require a separate lifecycle assessment.

For financial and environmental calculations: cost one complete monitoring unit per pallet, then add installation, network data, replacement probes / storage cards and end-of-life electronics handling. Supplier prices, rated equipment lifetime and field energy consumption were not assumed in this prototype.